Four Charging Guns DC Fast EV Charger Product Specification
|
Outlet Specifications |
|||
| Connection standard |
CCS Combo2 (IEC 61851-23) |
CHAdeMO 1.2 |
IEC 61851-1 |
| Connector/socket type |
IEC62196-3 CCS Combo2 Mode 4 |
CHAdeMO Mode 4 |
IEC 62196-2 Type 2 Mode 3 |
| Vehicle Safety Communication |
CCS Combo2 – IEC 61851-23 over PLC |
CHAdeMO – JEVS G105 over CAN |
IEC 61851-1 PWM (AC Type 2) |
| System output voltage range |
150-500VDC |
400/415VAC |
|
| Number of output interface configuration modules |
21kW×3 |
21kW×3 |
22kW×1 |
| Connector maximum output current |
150A |
125A |
32A |
| Communication interface |
PLC |
CAN |
PWM |
| Cable length |
5m |
5m |
5m |
| Dimensions (D x W x H) |
600×690×1500 mm |
||
|
Input Specifications |
|||
| AC Supply System |
Three-Phase, 5 Wire AC system (3Ph.+N+PE) |
||
| Input Voltage (AC) |
3Ø, 260~530VAC |
||
| Input Frequency |
50Hz±10Hz |
||
| Input Supply Failure backup | Battery backup for minimum 1 hour for the control system and billing unit. Data logs should be synchronized with CMS during back up time, in case battery drains out |
||
|
Environment Parameter |
|||
| Applicable Scene |
Indoor/Outdoor |
||
| Operating temperature |
﹣20°C to 50°C(de-rating characteristic applies)Option:﹣20°C to 50°C |
||
| Storage Temperature |
﹣40°C to 70°C |
||
| Maximum altitude |
Up to 2000m |
||
| Operating humidity |
≤95% non-condensing |
||
| Acoustic noise |
<65dB |
||
| Maximum altitude |
Up to 2000m |
||
| Cooling method |
Air cooled |
||
| Protection level |
IP54,IP10 |
||
|
Power Module |
|||
| Max Output Power per Module |
21kW |
||
| Max Output Current per Module |
50A |
||
| Output voltage range for each module |
150-500VDC |
||
| Converter Efficiency |
Maximum efficiency >95% |
||
| Power facto |
Rated output load PF ≥ 0.99 |
||
| Voltage regulation accuracy |
≤±0.5% |
||
| Current sharing accuracy |
≤±0.5% |
||
| Steady flow accuracy |
≤±1% |
||
|
Feature Design |
|||
| Interaction Display |
Full-color (7 in 800x480 TFT ) LCD display for driver interaction |
||
| Payments |
Smart Card, Server based Online Payments or equivalent |
||
| Network connection |
GSM / CDMA / 3G modem, 10/100 Base-T Ethernet |
||
| Communication Protocol |
OCPP1.6(optional) |
||
| Visual Indicators |
Error indication, Presence of input supply indication, Charge process indication and other relevant information |
||
| Push Button |
Mushroom type emergency stop switch (Red) |
||
| RFID system |
ISO/IEC14443A/B, ISO/IEC15693, FeliCa™ 1, NFC reader mode, LEGIC Prime & Advant |
||
|
Safe Protection |
|||
| Protection | Over current, under voltage, over voltage, Residual current, Surge protection, Short circuit, Earth fault at input and output, Input phase reversal, Emergency shut-down with alarm, Over temperature, Protection against electric shock | ||